c
产品展示 CGDP-523.5-S-50 523.5nm 单纵模绿光激光器 详细内容 If you utilize NIR spectroscopy for research, process or diagnostics, NIRQuest is a less costly, less complex alternative to FT-IR and comparable technologies. NIRQuest delivers a high-performance optical bench with low-noise electronics and more grating options than we've ever offered. This compact, multi-interface spectrometer is available in version for 900-1700 nm, 900-2050 nm, 900-2200 nm and 900-2500 nm. NIRQuest's modular design delivers more customization for a wider variety of applications including medical diagnostics, pharmaceuticals analysis, environmental monitoring and process control. NIRQuest for Laser Analysis NIRQuest is versatile enough to be configured for high-resolution laser and optical fiber characterization. The NIRQuest delivers reliable optical resolution to 15000:1 @ 100 ms integration >13000:1 @ 1000 ms integration >10000:1 @ 100 ms integration 10000:1 @ 100 ms integration 7500:1 @ 10 ms integration A/D resolution: 16-bit 16-bit 16-bit 16-bit Dark noise: 6 RMS counts @ 100 ms 12 RMS counts @ 1000 ms 6 RMS counts @ 100 ms 12 RMS counts @ 250 ms 6 RMS counts @ 100 ms 12 RMS counts @ 250 ms 8 RMS counts @ 10 ms 12 counts RMS @ 30 ms Dynamic range: 15 x 10^6 (system); 5000:1 for a single acquisition 15 x 10^6 (system); 1000:1 for a single acquisition 5 x 10^6 (system); 5000:1 for a single acquisition 3 x 10^5 (system); 5000:1 for a single acquisition Integration time5: 1 ms-10 seconds 1 ms-2000 ms 1 ms-2000 ms 1 ms-60 ms Corrected linearity: >99.8% >99.8% >99.8% >99.8% Computer interfaces: USB 2.0 @ 480 Mbps; RS-232 (2-wire) @ 115.2 K baud Wireless (Wi-Fi) interface: Yes, with Remora adapter Wi-Fi range: 25 meters in free space 1 Useable range?is defined in the context of the NIRQuest models detector response and its typical grating response. For example, the 512-element detector has response at 850 nm, but grating response begins at 900 nm. The G9206 256-element detector response is sensitive to TEC temperature, and has response only to 2050 nm when the TEC is set to -20 C. The G9208 256-element detector has response to 2550 nm, but the grating efficiency drops off at 2500 nm. 2 Other filter options are available for order-sorting in the NIRQuest256-2.1 and NIRQuest256-2.5. Please contact an Applications Scientist for details. 3 Optical resolution (FWHM) depends on grating and slit selection. 4 SNR will decrease at longer integration times. 5 Maximum integration times are defined as the longest amount of time one can integrate the spectrometer before the dark level rises to half of full scale.